Notice: Temporary Suspension of New Experiment Creation
We have temporarily disabled the creation of new experiments as we are continuously running out of space. This issue has been impacting both uploads and downloads from FlowRepository. By taking this step, we aim to make downloads of existing data more reliable.
We apologize for the inconvenience and appreciate your understanding as we work on upgrading our hardware and improving the overall solution.
Thank you for your patience.

Download-button_s

Experiment Overview

Repository ID: FR-FCM-Z5RJ Experiment name: 24-color (30-marker) antibody panel for deep immunophenotyping of immune cells in human peripheral blood MIFlowCyt score: 65.50%
Primary researcher: Arkadiusz Pierzchalski PI/manager: Arkadiusz Pierzchalski Uploaded by: Arkadiusz Pierzchalski
Experiment dates: 2020-01-06 - 2022-08-31 Dataset uploaded: Oct 2022 Last updated: May 2023
Keywords: [T cell] [monocyte] [B cell] [dendritic cells] [regulatory T cells] [NK cell] [iNKT cells] [full spectrum flow cytometry] [High dimensional flow cytometry] [Immune profiling] [NKT-like cell] [Naïve and Memory T cells] [ILCs] [gdT cells MAIT cells] Manuscripts: Cytalogo
Organizations: Helmholtz-Centre for Environmental Research -UFZ, Environmental Immunology, Leipzig, Saxony (Germany)
Purpose: This OMIP provides a detailed description of a 24-color (30-markers) full spectrum flow cytometry panel to identify all major immune compartments of blood, neutrophils, basophils, eosinophils as well as T, B, MAIT, Treg, NK, NKT-like, ?? T, monocytes and dendritic cells, basophils, ILCs and their associated subsets. Activation, differentiation, check point and senescence markers were employed to provide an in-depth immune profiling in a single sample.
Conclusion: Full Spectrum Flow Cytometry allows detection of 30 markers simultaneously with good population resolution, allowing comprehensive in-depth immune cell profiling within a single biological sample.
Comments: Unmixed data file with FlowJo workspace datafile used in OMIP as an example.
Funding: Not disclosed
Quality control: Daily QC was performed using SpectroFlo® QC beads prior to acquiring samples to ensure that the cytometer was performing optimally. Daily QC assessed the instrument’s optical alignment and the system performance drift by measuring %rCVs and gains needed to place the beads at the target locations established for each detector. During the typical QC protocol, Laser delays and area scaling factors were also optimized, and gain settings adjusted to account for day-to-day instrument variability.
Download FCS Files or login and see the dataset in your inbox for further annotation details.