Notice: Temporary Suspension of New Experiment Creation
We have temporarily disabled the creation of new experiments as we are continuously running out of space. This issue has been impacting both uploads and downloads from FlowRepository. By taking this step, we aim to make downloads of existing data more reliable.
We apologize for the inconvenience and appreciate your understanding as we work on upgrading our hardware and improving the overall solution.
Thank you for your patience.

Download-button_s

Experiment Overview

Repository ID: FR-FCM-ZZTK Experiment name: Fibroblast surface markers MIFlowCyt score: 75.22%
Primary researcher: Zuzana Kahounová PI/manager: Karel Soucek Uploaded by: Zuzana Kahounová
Experiment dates: 2014-12-01 - 2017-01-31 Dataset uploaded: Aug 2016 Last updated: Apr 2017
Keywords: [anti-fibroblast] [fibroblast activation protein α] [fibroblast surface protein] [epithelial-to-mesenchymal transition] [cancer-associated fibroblasts] Manuscripts: [28383825] Cytalogo
Organizations: Institute of Biophysics AS CR, v.v.i., Department of Cytokinetics, Brno, (Czech Republic)
Purpose: The purpose of this experiment was to use comercially available antibodies detecting surface markers of fibroblasts and verify their specificity on the panel of human fibroblast cells and also cells of epithelial origin. Namely, anti-FAP antibody, anti-FSP antibody and anti-fibroblast antibody were tested.
Conclusion: Obtained results indicate that none of tested markers was expressed only on fibroblasts, but variable expression on cells of epithelial origin was detected. Therefore, combination of markers for both positive and negative selection of fibroblast is adviced in order to identify fibroblasts unequivocaly.
Comments: None
Funding: Not disclosed
Quality control: Cell debris, doublets, and aggregates were excluded from analysis based on a dual-parameter dot plot in which the pulse ratio (signal area/signal high; y-axis) versus signal area (x-axis) was displayed. Dead cells were excluded from analyses using LIVE/DEAD® Fixable Dead Cell Stain Kit. The automatic compensation for multicolor immunofluorescence analysis was performed using UltraComp eBeads (eBioscience), Anti-mouse IgG kappa/negative control (FBS) compensation particles set (BD Biosciences), and ArC Amine Reactive Compensation Bead Kit (Thermo Fisher Scientific). Compensation matrix was calculated either using FlowJo or FACSuite software (BD Biosciences), or manually corrected.


Experiment variables

Sample Type
· PY005 PY005 FAP.fcs · PY005 FSP.fcs · PY005 af488.fcs · PY005 anti-fib+CD24.fcs · PY005 iso rea+mouse BV421.fcs
· 1329 1329 nontumor FAP.fcs · 1329 nontumor FSP.fcs · 1329 nontumor iso.fcs · 1329 tumor FAP.fcs · 1329 tumor FSP.fcs · 1329 tumor iso.fcs

Download FCS Files or login and see the dataset in your inbox for further annotation details.